FLB/TLB-2x-Scope V1.0 (KW 09/2006 - 03.03.2006) 9
Appendix:
Technical Data: FLB-CON2-2X
Voltage supply +12VDC ... +30VDC, reverse-polarity protected, overload protected
Current consumption with sensor: typ. 80 mA
Operating temperature range -20°C to +60°C
Storage temperature range -20°C to +85°C
Housing aluminum, anodised in blue
Housing dimensions LxWxH ca. 60 mm x 40 mm x 22 mm (without connector)
Enclosure rating IP 64
Outputs (REF1, REF2) 2x digital (adjustable under Windows®):
npn n.c. / pnp n.o.; pnp n.c. / npn n.o.
Serial interface
RS232, parameterisable under Windows®
Switching state indication by means of an orange LED (integrated in the M8 connector)
Pulse lengthening adjustable under Windows® (0 ms ... 100 ms)
Sensitivity adjustable under Windows®
Type of connector 4-pole M8 connector (PLC),
5-pole female connector type Binder 712 (PC),
connector for FLB sensor frontend
Max. switching current 200 mA, short-circuit proof
Switching frequency Depends on AVERAGE setting:
AVERAGE Switching frequency
1 32 kHz
2 16,2 kHz
4 9,19 kHz
8 4,98 kHz
16 2,6 kHz
32 1,3 kHz
64 677 Hz
128 340 Hz
256 170 Hz
512 85 Hz
1024 42,7 Hz
2048 21,4 Hz
4096 10,7 Hz
8192 5,35 Hz
16384 2,67 Hz
32768 1,33 Hz
EMC test acc. to IEC - 801 .. CE
Suitable sensor frontends FLB-F-..., FLB-H-..., FLB-V-...